
Sleep Restfully, Inc.
3315 Marquart St., Suite 209, Houston, TX 77027
(866) 923-2727 (281) 840-4504 Fax:(800) 540-5078 (281) 501-7969


|
|
| |
 |
 |
 |
Philips Respironics System One REMstar
PRO CPAP
DISCONTINUED - REPLACED WITH PR SYSTEM ONE 60 SERIES
System
Contents
REMstar
PRO CPAP
with
C-Flex+ system includes the following items:
-
Device
-
Side cover
panel
-
User manual
-
SD card
-
Carrying
case
-
Reusable
gray foam filter
-
Flexible
tubing
-
Disposable
ultra-fine filter (optional)
-
Power cord
and power supply
-
Humidifier
(optional)
While in Auto-Trial phase,
AutoIQ will use our proven auto algorithm to provide
breathby-breath therapy, for a single day or for multiple
days adding up to a total of 30 days. By learning your
patient’s breathing patterns and treatment needs during
the trial phase, Auto-Trial is smart enough to identify an
ideal therapy pressure specifically for that patient. The
device will automatically deliver the pressure the patient
was at or below 90% of the time, or it will deliver a
fixed pressure that has been set by the clinician.
Clinicians can opt to use all
30 Auto-Trial days up front or choose to use a shorter
trial period and save the balance for a later date –
adding to your convenience should a patient’s conditions
or needs change. For example, if you choose to use only
seven days of the Auto-Trial phase at the start of a
patient’s treatment, you will have 23 available days
remaining should an important change in your patient’s
condition occur, such as a significant weight loss or
gain. This process can be repeated until you use the
entire 30 days of Auto-Trial functionality on a given
device – and the 30 days never expire.
With the Auto-Trial phase and
AutoIQ, the control, choice, and flexibility are yours.
Once the ideal pressure is established, the Auto-Check
phase evaluates the patient’s events every 30 hours to
determine if a pressure change is needed. If there is no
need for an adjustment, the pressure will remain the same.
However, if after 30 hours the device determines that the
pressure should be adjusted, it will automatically raise
or lower the pressure 1 cm at a time, or remain at the
same pressure, with an upper and lower limit of 3 cm H2O.
Introducing a new level of
intelligence and control
REMstar Pro with AutoIQ is continually
curious about your patients’ treatment needs and smart
enough to help you deliver exceptional patient therapy
month after month, even when you’re miles away.
Introducing the AutoIQ mode.
Ideally, you
want to be able to track a patient's progress over
several nights, establish an ideal therapy pressure, and
then check back periodically just to make sure therapy
is still optimal. In reality, providing that level of
service to every patient is neither practical nor
equitable. That’s where the AutoIQ mode comes in. With
two distinct phases – Auto- Trial and Auto-Check –
AutoIQ (available in the REMstar Pro) uses the proven
Philips Respironics auto algorithm to track and deliver
breath-by-breath therapy and set an ideal fixed
pressure. It then reassesses treatment needs
periodically and changes therapy pressures automatically
– without the need for you to send someone to the
patient’s home. AutoIQ is one intelligent solution that
is always curiously smart and powerfully convenient.
The result
of a shared commitment
Sharing your
dedication to allowing more people to enjoy the benefits
of better sleep and brighter days, Philips Respironics
is committed to developing meaningful innovations that
help us all get one step closer to making patient
success automatic. The AutoIQ mode is evidence of that
shared mission and of our ongoing pledge to you and your
patients.
The 30/30 advantage
Auto-Trial
phase
For a single
day or for multiple days adding up to a total of 30
days, AutoIQ will provide breath-by-breath therapy while
in Auto-Trial phase, using our existing, proven auto
algorithm. By learning your patient’s breathing patterns
and treatment needs during the trial phase, Auto-Trial
is smart enough to then identify an ideal therapy
pressure specifically for that patient. The device will
automatically deliver the pressure that the patient was
at or below 90% of the time or a fixed pressure that has
been set by the clinician. Clinicians can opt to use all
30 Auto-Trial days up front or choose to use fewer trial
days and save the balance for a later date if the
patient’s condition changes. For example, if you choose
to use only seven days of the Auto-Trial phase at the
start of a patient’s treatment, you will still have 23
available days remaining should an important change in
your patient’s condition occur, such as a significant
weight loss or gain.
System One REMStar PRO
CPAP
Specifications:
| Pressure range: |
4 to 20 cm H2O |
 |
| Flex pressure relief: |
Mode specific |
 |
| Ramp time: |
0 to 45 min.
(5-min. increments) |
 |
| Starting ramp pressure: |
4 to CPAP;
patient-adjustable
4 to min. pressure |

N/A |
| Dimensions: |
7" L x 5.5" W x 4" H
18 cm L x 14 cm W x 10 cm H |
 |
| Weight: |
3 lbs; 1.36 kg (without humidifier) |
 |
| Filters: |
Foam and optional ultra-fine |
 |
| Device set-up: |
LCD/control wheel/push button |
 |
| Data storage capacity (minimum): |
Display: Compliance VIC 7- and 30-day averages
SD Card: >1 year
On-board: up to 6 months |
 |
| Compliance meter: |
Breathing detection |
 |
| Altitude compensation: |
Automatic
Manual |

N/A |
| Electrical requirements: |
100 - 240 VAC, 50/60 Hz |
 |
| Humidification: |
Integrates with REMstar System One heated humidifier
and REMstar pass-over humidifier |
 |
| Warranty: |
Two years; replace with new |
 |
| Miscellaneous: |
Fine pressure calibration
Lighted LEDs |
N/A
 |
|
 |
 |
 |
 |
 |
|
|
| |
Customer Services
Contact Us
About Us
Returns Policy
Warranty Information
Insurance Information
Privacy Information
Prescriptions Policy
Articles
Make a Payment
|
 |
Quick Links
ResMed CPAP
Philips Respironics CPAP
BiPAP & VPAP Machines
ResMed CPAP Mask
Philips Respironics EverGo
Inogen One G2
SeQual Eclipse 3
SimplyGo Portable Oxygen Concentrator
|
 |
Resources
CPAP Mask Comparison Chart
CPAP Machine Comparison Chart
BiPAP & VPAP Comparison Chart
Portable Oxygen Concentrator
Comparison Chart
Oxygen Concentrator Comparison Chart
ResMed Equipment & Supplies
Philips Respironics Equipment &
Supplies
|
 |
|
© ResMed 2010
Use of the ResMed images, and materials is
made with the permission of ResMed. ResMed owns the copyright in the
text, images, drawings and materials
and ResMed reserves all
rights. All services provided by SleepRestfully.com are independent
of ResMed. We only sell ResMed products to end users residing in the
United States.
The DeVilbiss Healthcare IntelliPAP was designed and
intended for sale and use to patients in the US, Canada, Mexico
only. Medical product requirements, regulations and support
differ by country.
CPAP, BiPAP & Portable
Oxygen Concentrators from ResMed, Philips Respironics,
Fisher & Paykel, DeVilbiss, Inogen, Invacare & SeQual
Copyright 2007-2012
|
|
|
|
|
|
|
|
|